Last Update: 29 April, 2008
Group Companies
Delta Electronics Group
Delta Electronics, Inc.
Delta Networks, Inc.
Delta Electronics (Thailand) Public Company Ltd.
>> Home / Products / Sensor(Pt-RTD)
| Passive Components | Power Choke | RF Component| Sensor (Pt-RTD) | Power Modules|
Paired Pt sensors for Calorimeter

Calorimeter sensors are used in calorimeters to measure water temperatures and to determine transported heat volume through warm water pipes for billing purpose of heat counters and district heating operators. Therefore, it requires high precision and long-term stability. The measurement equipments Cyntec uses to ensure these requirements are as following:

 
High precision oil bath
  Operating temperature: 0¢J~105¢J
  Temperature stability: ¡Ó0.01¢J
  Accuracy: ¡Ó0.005¢J
 
HP 34401 and others
The products meet the definition and regulation of IEC-751, Class B:
¡µt=¡Ó(0.30+0.005x t )

Besides, they meet the requirements of EN1434:
Et=¡Ó(0.5+3x¡µ£pmin/¡µ£p)%
Et:the relative measuring deviation due to temperature deviation
£p: water temperature difference between input and output
£pmin: minimum temperature difference (by 3)

Every piece (pair) of calorimeter sensor to be shipped is measured with the below mentioned three temperature points to ensure its accuaracy, and the measurement data are released to customers for record when shipments are effected. The maximum temperature deviation for the same temperature point among a pair of the clarometer sensors, 0.1¢J is quaranteed.
0¢J
50¢J
100¢J

In addition to being QS 9000 / ISO 9001 Certified, Cyntec has the ¡§Certificate of Independent Test Laboratory Approval ISO/IEC 17025¡¨ and ¡§CNLA (Chinese National Laboratory Accreditation)¡¨ high quality products can be difinitely ensured.
 
Specification
 
 
 
   
 
   